Up-to-date reference of API arguments for DLB monitor you can get at documentation portal
opentelekomcloud_lb_monitor_v3¶
Manages a Dedicated LB monitor (health check) resource within OpenTelekomCloud.
Example Usage¶
resource "opentelekomcloud_lb_loadbalancer_v3" "lb" {
name = "loadbalancer_1"
router_id = data.opentelekomcloud_vpc_subnet_v1.shared_subnet.vpc_id
network_ids = [data.opentelekomcloud_vpc_subnet_v1.shared_subnet.network_id]
availability_zones = [var.availability_zone]
}
resource "opentelekomcloud_lb_pool_v3" "pool" {
loadbalancer_id = opentelekomcloud_lb_loadbalancer_v3.lb.id
protocol = "HTTP"
lb_algorithm = "ROUND_ROBIN"
}
resource "opentelekomcloud_lb_monitor_v3" "monitor" {
pool_id = opentelekomcloud_lb_pool_v3.pool.id
type = "HTTP"
delay = 3
timeout = 30
monitor_port = 8080
max_retries = 5
max_retries_down = 1
}
Argument Reference¶
The following arguments are supported:
admin_state_up
- (Optional) Specifies the administrative status of the health check.true
indicates that the health check is enabled, andfalse
indicates that the health check is disabled.Default:
true
pool_id
- (Required) Specifies the ID of the backend server group for which the health check is configured. Changing this creates a new monitor.type
- (Required) Specifies the health check protocol.The value can be
TCP
,UDP_CONNECT
,HTTP
,HTTPS
, orPING
.delay
- (Required) Specifies the interval between health checks, in seconds.The value of this parameter ranges from 1 to 50.
timeout
- (Required) Specifies the maximum time required for waiting for a response from the health check, in seconds.The value of this parameter ranges from 1 to 50.
It is recommended that you set the value less than that of parameter
delay
.max_retries
- (Required) Specifies the number of consecutive health checks when the health check result of a backend server changes fromOFFLINE
toONLINE
.The value ranges from 1 to 10.
max_retries_down
- (Optional) Specifies the number of consecutive health checks when the health check result of a backend server changes fromONLINE
toOFFLINE
.The value ranges from 1 to 10.
Default value is 3
monitor_port
- (Optional) Specifies the port used for the health check. If this parameter is left blank, the port of the backend server group will be used by default.name
- (Optional) Specifies the health check name.project_id
- (Optional) Specifies the project ID. Changing this creates a new monitor.domain_name
- (Optional) Specifies the domain name that HTTP requests are sent to during the health check.This parameter is available only when type is set to
HTTP
.The value is left blank by default, indicating that the virtual IP address of the load balancer is used as the destination address of HTTP requests.
The value can contain only digits, letters, hyphens (-), and periods (.) and must start with a digit or letter.
url_path
- (Optional) Specifies the HTTP request path for the health check.The value must start with a slash (/), and the default value is
/
.This parameter is available only when
type
is set toHTTP
.expected_codes
- (Optional) Specifies the expected HTTP status code. This parameter will take effect only whentype
is set to HTTP.The value options are as follows:
A specific value, for example,
200
A list of values that are separated with commas (,), for example,
200, 202
A value range, for example,
200-204
Default:
200
http_method
- (Optional) Specifies the HTTP method.The value can be
GET
,HEAD
,POST
,PUT
,DELETE
,TRACE
,OPTIONS
,CONNECT
, orPATCH
.This parameter will take effect only when type is set to
HTTP
.
Attributes Reference¶
In addition to all arguments above, the following attributes are exported:
id
- Specifies the health check (monitor) ID.
Import¶
Load Balancer Monitor can be imported using the monitor ID, e.g.:
terraform import opentelekomcloud_lb_monitor_v3.monitor b4ef7345-cf1a-41ca-8baa-941466a66853