Modifying Specifications of a Protected Instance¶
Scenarios¶
If the specifications of an existing protected instance cannot meet the service requirements, you can perform steps provided in this section to modify the server specifications, including the vCPU and memory.
The following scenarios may involve:
Modifying the specifications of both the production and DR site servers
Modifying the specifications of the production site server only
Modifying the specifications of the DR site server only
Prerequisites¶
The protection group is in the Available or Protecting state.
The protected instance is in the Available, Protecting, or Modifying specifications failed.
Servers of which the specifications to be modified are stopped.
Procedure¶
Log in to the management console.
Click Service List and choose Storage > Storage Disaster Recovery Service.
The Storage Disaster Recovery Service page is displayed.
In the pane of the protection group for which the protected instance specifications are to be modified, click Protected Instances.
The operation page for the protection group is displayed.
On the Protected Instances tab, locate the row containing the target protected instance, click More in the Operation column, and choose Modify Production Site Server Specifications or Modify DR Site Server Specifications from the drop-down list.
In the displayed dialog box, select new server type, vCPU, and memory specifications.
(Optional) If you need to modify the specifications of both the production site server and DR site server, select Modify the specifications of both the production and DR site servers. After you select this item, the system will modify the specifications of both the production site server and DR site server to the same specifications.
Note
This item is deselected by default, indicating that the system modifies the specifications of only the production site server or DR site server.
Click OK.
To ensure proper server running, do not perform any operations to the servers during specification modifications.