System Container Exits Unexpectedly

Symptom

After a training job is created, the system container exits unexpectedly.

Possible Causes

The possible causes are as follows:

  1. An error occurred in OBS.

    1. Unavailable file: The specified key does not exist.

    2. Insufficient OBS permissions

    3. OBS traffic limiting

    4. Others

  2. The disk space is insufficient.

Solution

  1. For an OBS error:

    1. Unavailable file: The specified key does not exist.

      For details, see Error Message "errorMessage:The specified key does not exist" Displayed in Logs.

    2. Insufficient OBS permissions

      For details, see What Should I Do If Error "stat:403 reason:Forbidden" Is Displayed in Logs When a Training Job Accesses OBS.

    3. OBS traffic limiting

      For details, see Error Message "BrokenPipeError: Broken pipe" Displayed When OBS Data Is Copied.

    4. Others

      Alternatively, collect the request ID and contact OBS customer service.

  2. For insufficient disk space:

    For details, see Common Issues Related to Insufficient Disk Space and Solutions.