ALM-19012 HBase System Table Directory or File Lost¶
Description¶
The system checks whether HBase directories and files exist on the HDFS every 120 seconds. This alarm is generated when the system detects that the files or directories do not exist. This alarm is cleared when the files or directories are restored.
The HBase directories and files are as follows:
Directory of the namespace hbase on the HDFS
hbase.version file
Directory of the table hbase:meta on the HDFS, .tableinfo file, and .regioninfo file
Directory of the table hbase:namespace on the HDFS, .tableinfo file, and .regioninfo file
Directory of the table hbase:hindex on the HDFS, .tableinfo file, and .regioninfo file
Directory of the hbase:acl table on the HDFS, .tableinfo, and .regioninfo file (This table does not exist in the common mode cluster by default.)
Attribute¶
Alarm ID | Alarm Severity | Automatically Cleared |
---|---|---|
19012 | Critical | Yes |
Parameters¶
Name | Meaning |
---|---|
Source | Specifies the cluster for which the alarm is generated. |
ServiceName | Specifies the service for which the alarm is generated. |
RoleName | Specifies the role for which the alarm is generated. |
HostName | Specifies the host for which the alarm is generated. |
Impact on the System¶
The HBase service fails to restart or start.
Possible Causes¶
Files or directories on the HDFS are missing.
Procedure¶
Locate the alarm cause.
On the FusionInsight Manager, choose O&M > Alarm > Alarms. Click this alarm and check whether Alarm Cause indicates unknown errors.
On the FusionInsight Manager home page, choose O&M > Backup and Restoration > Backup Management. Check whether there are success records of the backup task named default or other HBase metadata backup tasks that have been successfully executed.
Use the latest backup metadata to restore the metadata of the HBase service.
Collect fault information.
On the FusionInsight Manager page of the active and standby clusters, choose O&M > Log > Download.
In the Service area, select faulty HBase services in the required cluster.
Click in the upper right corner, and set Start Date and End Date for log collection to 10 minutes ahead of and after the alarm generation time, respectively. Then, click Download.
Contact the O&M personnel and send the collected logs.
Alarm Clearing¶