• MapReduce Service

mrs
  1. Help Center
  2. MapReduce Service
  3. User Guide
  4. MRS Manager Operation Guide
  5. Alarm Reference
  6. ALM-12015 Partition Filesystem Readonly

ALM-12015 Partition Filesystem Readonly

Description

The system checks the partition status periodically. This alarm is generated when the system detects that a partition to which service directories are mounted enters the read-only mode (due to a bad sector or a faulty file system).

This alarm is cleared when the system detects that the partition to which service directories are mounted exits from the read-only mode (because the file system is restored to read/write mode, the device is removed, or the device is formatted).

Attribute

Alarm ID

Alarm Severity

Automatically Cleared

12015

Major

Yes

Parameters

Parameter

Description

ServiceName

Specifies the service for which the alarm is generated.

RoleName

Specifies the role for which the alarm is generated.

HostName

Specifies the host for which the alarm is generated.

DirName

Specifies the directory for which the alarm is generated.

PartitionName

Specifies the device partition for which the alarm is generated.

Impact on the System

Service data fails to be written into the partition, and the service system runs abnormally.

Possible Causes

The hard disk is faulty. For example, a bad sector exists.

Procedure

  1. On MRS Manager, click the alarm in the real-time alarm list.
  2. In the Alarm Details area, obtain HostName and PartitionName from LocationHostName is the node where the alarm is reported, and PartitionName is the partition of the faulty disk.
  3. Contact hardware engineers to check whether the disk is faulty. If the disk is faulty, remove it from the server.
  4. After the disk is removed, alarm ALM-12014 Partition Lost is reported. Handle the alarm. For details, see ALM-12014 Partition Lost. After the alarm ALM-12014 Partition Lost is cleared, alarm ALM-12015 Partition Filesystem Readonly is automatically cleared.

Related Information

N/A