Description

At 00:00 every day, the system starts checking whether user ommdba and its password are about to expire every 8 hours. This alarm is generated when the user or password is going to expire in 15 days.

It is cleared when the validity period of user ommdba is changed or the password is reset and the alarm handling is complete.

Attribute

Alarm ID

Alarm Severity

Automatically Cleared

12032

Major

Yes

Parameters

Parameter

Description

ServiceName

Specifies the service for which the alarm is generated.

RoleName

Specifies the role for which the alarm is generated.

HostName

Specifies the host for which the alarm is generated.

Impact on the System

The OMS database cannot be managed and data cannot be accessed.

Possible Causes

User ommdba or its password is about to expire.

Procedure

  1. Check whether user ommdba and its password in the system are valid.

    1. Log in to the faulty node.
    2. Run the following command to view information about user ommdba and its password:

      chage -l ommdba

    3. Check whether the user and password are about to expire based on the system message.
      1. View the value of Password expires to check whether the password is about to expire.
      2. View the value of Account expires to check whether the user is about to expire.
      NOTE:

      If the parameter value is never, the user and password are valid permanently; if the value is a date, check whether the user and password are going to expire within 15 days.

    4. Modify the validity period configuration:
      • Run the following command to set a validity period for user ommdba:

        chage -E 'specified date' ommdba

      • Run the following command to set the number of validity days for user ommdba:

        chage -M 'number of days' ommdba

    5. Check whether the alarm is cleared automatically in the next periodic check.
      • If yes, no further action is required.
      • If no, go to Step 2.

  2. Collect fault information.

    1. On MRS Manager, choose System > Export Log.
    2. Contact technical support engineers for help, detail see technical support.

Related Information