How Do I Handle the Failure to Ping a CentOS 7 Extension NIC?¶
Cause¶
A known kernel issue of the OS
Note
CentOS 7.4 and earlier CentOS 7 have this issue.
Solution¶
This issue has been rectified in CentOS 7.5. To use extension NICs, you are advised to use CentOS 7.5 or upgrade the OS kernel version to 3.10.0-862. (In quick provisioning scenarios, you can only resolve this issue by changing the OS to CentOS 7.5.).
Upload the CentOS 7.5 kernel file downloaded from the official website to the BMS and run the following command to update the kernel:
yum install kernel-3.10.0-862.el7.x86_64.rpm
Note
If you have configured automatic EVS disk attaching to the BMS in /etc/fstab, comment out the corresponding configuration item in /etc/fstab. Otherwise, you may fail to enter the BMS OS when restarting the BMS.
Restart the OS. After entering the OS, reinstall the SDI iNIC driver, RAID controller card driver, and IB driver for CentOS 7.5 by following the instructions in the Bare Metal Server Private Image Creation Guide.