Viewing Alarms

Procedure

  1. In the navigation pane, choose Alarm Center > Alarm List.

  2. View alarms on the Alarm List page.

    1. Set a time range to view alarms. There are two methods to set a time range:

      Method 1: Use the predefined time label, such as Last 1 hour, Last 6 hours, or Last 1 day. Select one as required.

      Method 2: Specify the start time and end time to customize a time range. You can specify up to 15 days.

    2. Set filter criteria and click image1 to view the alarms generated in the period.

  3. Perform the operations listed in Table 1 as required.

    Table 1 Operations

    Operation

    Method

    Description

    Viewing alarm statistics

    Click Show Graph, and view alarm statistics that meet filter criteria within a specific time range on a bar graph.

    -

    Clearing alarms

    In the alarm list, click image2 in the Operation column of the target alarm.

    • You can clear alarms after the problems that cause them are resolved.

    • You can view the alarms that have been cleared on the History tab page.

    Viewing alarm details

    View alarm details in the Alarm Detail column.

    -